Brooks Rand Labs

contact us   |   about brooks rand labs   |   analytical services division   |   instrument manufacturing division

BROOKS RAND LABS HOME
INSTRUMENT MANUFACTURING
MODEL III
Guru™ SOFTWARE
AUTOMATED ANALYZERS
TOTAL Hg SYSTEMS
MMHg SYSTEMS
MORE INFORMATION
REQUEST A QUOTE
METHODS & RESOURCES
DATABASE / CATALOG

NEED MORE INFO?

Contact Brooks Rand Labs to receive detailed information about our products.

Total Hg Systems

The Brooks Rand mercury systems are specifically designed for mercury analysis by EPA Method 1631.

1631 Systems

The standard Brooks Rand 1631 system combines easy to use automated analysis with manual purge and trap for a high throughput, cost effective system. This system consists of the Model III and the Amalgamation Control Module for automated trap analysis, along with the manual Purge and Trap Module. This semi-automated system allows for the simultaneous purging of multiple samples while previously loaded amalgamation traps are analyzed. The result is a throughput rate of less than 5 minutes per sample.

Air Monitoring Systems

Indoor and outdoor air monitoring systems consist of a gas-sampling pump, the Model III, and the Amalgamation Control Module.

245.7 Systems

Manual 245.7 can easily be performed using the Model III, a ball flowmeter, and a multi-channel pump.

All systems come complete with the Brooks Rand Guru™ Software for system control and peak integration.

Amalgamation Control Module

VERSATILE
Can be used with the Model III for all Method 1631 systems and for total mercury air analysis and monitoring systems.

SIMPLE OPERATION
Automates analysis from gold amalgamation trap with a single keystroke from Advanced Mercury Guru™ Software.

“ZERO” FOOTPRINT
The ACM is the same footprint as the Model III and can be stacked with the Model III, thereby taking up no additional lab bench space.

ApplicationsFor total mercury analysis of oxidized water samples (by EPA Method 1631), digested/oxidized solid samples (by Appendix to EPA Method 1631), and air samples.
DescriptionControls heating and cooling of gold amalgamation trap and carrier gas flow through the trap and detector.

Request full product description and specifications or a quote.

 

Purge and Trap Module

VERSATILE
Purge and trap modules are available in a variety of sizes ranging from 1 to 5 bubbler systems to match your throughput needs and budget.

ANALYST CONTROL
The manual purge and trap module allows ultimate flexibility for the analyst. Sample specific volumes and dilutions can be carried out to reduce the risks of overloading the system with mercury and to minimize reruns.

ApplicationsFor total mercury analysis of oxidized water samples (by EPA Method 1631) and digested/oxidized solid samples (by Appendix to EPA Method 1631).
DescriptionPerforms the reduction, volatilization, and trapping (using gold amalgamation) of oxidized liquid samples, and controls the purge gas flow rate.

Request full product description and specifications or a quote.